site stats

Cfgadm: insufficient condition

Webcfgadm:hardware component is busy, try again cfgadm:operation:configuration operation not supported on this machine cfgadm:operation:Data error:error_text cfgadm:operation:Hardware specific failure:error_text cfgadm:operation:Insufficient privileges cfgadm:operation:Operation requires a service interruption cfgadm:System is … WebThe cfgadm -l commands displays info about SCSI HBAs but not SCSI devices. Use the cfgadm -al command to display information about SCSI devices such as disk and tapes. In the following examples, only SCSI attachment points are listed. The attachment points displayed on your system will depend on your system configuration.

SCSI Hot Plugging With the cfgadm Command - Oracle

WebOct 5, 2024 · 1. Unconfigure and disconnect the FC HBA. # cfgadm -c unconfigure iou#0-pci#3. # cfgadm -c disconnect iou#0-pci#3. 2. Try to configure the new FC HBA: # … WebFeb 20, 2009 · cfgadm: Insufficient condition root@ 11:54:51 / $ cfgadm -f -c configure c4::500104 cfgadm: Library error: report LUNs failed: 500104 So what to do next? I … chris taylor moj https://berkanahaus.com

How to convert the cfgadm failing state to the intended ... - Veritas

WebApr 12, 2007 · System: Enterprise M5000 Server OS: Solaris 10 11/06 (U3), Generic_125100-04 Target: EMC CLARiiON CX3-20f cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::dsk/c0t1d0 disk connected configured unknown … Webcfgadm: Hardware specific failure: unconfigure N0.SB0: Insufficient memory cfgadm: Hardware specific failure: unconfigure N0.SB0: Memory operation failed Reduce the … WebThe cfgadm command provides configuration administration operations on dynamically reconfigurable hardware resources. These operations include displaying status, (-l), … chris taylor la dodgers baseball news

cfgadm(1m) [linux man page] - UNIX

Category:If cfgadm can see the target but no luns are listed in cfgadm then ...

Tags:Cfgadm: insufficient condition

Cfgadm: insufficient condition

FC-Cheats - pressy

WebOct 5, 2024 · Symptoms. The output of "cfgadm -al -o show_FCP_dev" shows FC HBA port LUNs in failed condition. Ap_Id Type Receptacle Occupant Condition. c9 fc-fabric connected unconfigured unknown. c9::50060exxxxxxxxxx unavailable connected unconfigured failed. c9::50060exxxxxxxxxx unavailable connected unconfigured failed. Webcfgadm: Insufficient condition . i get the message "Insufficient condition" with a wrong santinel configuration. Tue, 01 Jan 2008 01:53:26 GMT Page 1 of 1 [ 3 post ] Similar Threads: 1. Trying to setup firewall on linux box with two network cards, cards are not configuring correctly. 2.

Cfgadm: insufficient condition

Did you know?

WebMay 15, 2009 · 2,693, 19. You can skip the cfgadm unconfigure step and proceed to pull out the disk. Nothing would happen. just run devfsadm -C after you pull out and after you put in new disk and cont with your steps. usually cfgadm is used for scsi disks. V480 uses fcal disk if im not wrong. WebNov 20, 2009 · Solaris 10 M5000 would use cfgadm. For most newer machines/models on Solaris 10, cfgadm gets used rather than luxadm for disk replacement (ie: cfgadm does the tasks that would have been done by luxadm on older versions/older models. luxadm still can be used to display output/details of paths for applicable FC-AL, etc devices).

WebThe cfgadm command does some basic checking to prevent critical partitions from being disconnected, but it cannot detect all cases. Inappropriate use of this command can … Webcfgadm: hardware component is busy, try again cfgadm: operation: configuration operation not supported on this machine cfgadm: operation: Data error: error_text cfgadm: operation: Hardware specific failure: error_text cfgadm: operation: Insufficient privileges cfgadm: operation: Operation requires a service interruption

WebDisplaying IB Device Information by Using the cfgadm Command. To display IB device information, use the following command syntax: # cfgadm -[a]l. Including the –a option displays additional information.. The cfgadm command displays information about attachment points, which are locations in the system where DR operations can occur. … Webroot@solaris:~# cfgadm -c configure c4 cfgadm: Library error: report LUNs failed: 10000090fa02xxxx report LUNs failed: 500a098182eexxxx failed to create device node: 2001005056b1xxxx: I/O er Operation partially successful. Some failures seen. Extended emlxs logs from the host show PRLI sequence timeout. emlxs_msgbuf.out:(PRLI: …

WebUnconfiguring the board will prompt solaris to remove all processes from the cpu’s of the unconfigured boards and reschedule them on different cpu’s. Therefore, it is not …

WebJun 30, 2010 · $ cfgadm Ap_Id Type Receptacle Occupant Condition sata1/0 sata-port disconnected unconfigured failed $ cfgadm -c connect sata1/0 cfgadm: Insufficient condition I did a bit of searching and found this page: SolarisZfsReplaceDrive : use the -f … chris taylor nashville policeWebOct 5, 2024 · If cfgadm can see the target but no luns are listed in cfgadm then issue is in storage array (Doc ID 1941120.1) Last updated on OCTOBER 05, 2024. Applies to: … geometry games for third gradeWebThe cfgadm command has the following options. "ap_id" represents the PCI card's logical ID displayed by cfgadm. Options for display slot status information. No option Lists … chris taylor nztaWebThe following command unconfigures and electrically disconnects the card identified by pcie7: example# cfgadm -c disconnect pcie7. The change can be verified by entering the following command: example# cfgadm pcie7 Ap_Id Type Receptacle Occupant Condition pcie7 unknown disconnected unconfigured unknown. geometry gcse foundation questionsWebThese procedures use specific devices as examples to illustrate how to use the cfgadm command to hot-plug SCSI components. The device information that you supply, and that the cfgadm command displays, depends on your system configuration.. All of the procedures in this section require administrative privileges that are not generally granted … geometry.getindex is not a functionWebThe disk is shown as connected and configured in cfgadm, but the condition is listed as unusable: # cfgadm -al Ap_Id Type Receptacle Occupant Condition... sata0/0::dsk/c1t0d0 disk connected configured unusable sata0/1::dsk/c1t1d0 disk connected configured ok ... cfgadm: Insufficient condition ... chris taylor muncie inhttp://27.125.37.29/handbook/syshbk_cd/syshbk/collections/PROBLEMRESOLUTIONSURE/1-72-2049270.1-1.html geometry getinteriorpoint