I/o access error reading ob122
WebOB122 程序在出现 I/O 访问错误时被调用,例如当 CPU 程序访问一未定义的I/O 地址,CPU 会出现 I/O 访问错误,CPU 会调用 OB122,如果 OB122 未下载,CPU 会报故障停机。 … Web2 dec. 2024 · 1.用piw来访问硬件组态中不存在的地址时,每个扫描周期都会调用ob122。 2.从站掉电后,CPU不会调用OB122,即使是使用PIW访问。 西门子官方文档中关 …
I/o access error reading ob122
Did you know?
Web由编程错误引起的 stop 模式(ob 没有装载或不能装载,或没有 frb. 调试一个plc程序的时候,下载之后就sfc灯亮,看诊断是由编程错误引起的 stop 模式(ob 没有装载或不能装载, … WebI suspect it is being caused by an issue with an encoder under the machine, but I can't physically access it with it in it's current position. I'm reading that I can use OB122 to …
Web10 apr. 2024 · Global DB, byte access, Access address: 53 Requested OB: Programming error OB (OB121) Priority class: 1 Internal error, Incoming event vent 9 of 400: Event ID … Web20 apr. 2010 · Open HardwareConfig. Check which IO's are configured, write them down if needed. Open OB1. View > STL. In the first network write: A Ixx.x where xx.x is an input …
Web11 jun. 2006 · Once OB122 is called, relevant event info are stored in DB10 and bit M30.0 is set. You'll need to reset M30.0 to trap the next error. Of course, in case, you can … http://plctalk.net/qanda/showthread.php?t=71461
Web4 mrt. 2024 · This error means your CPU cannot read starting from address 280. As your description lacks a bit of info I will try to give you some things to check and maybe you …
Web2 dec. 2024 · 首先你先确定你的程序里有ob82 ob86 ob122 ob121等防止CPU自动由故障转为STOP的模块。 其次,如果你有这些模块还是引起了这样的故障,有两个可能,1CPU … fisher byglandWebThe following table describes the temporary (TEMP) variables for the I/O access error OB. The variable names are the default names of OB122. Variable Type Description … fisher c1p-2http://bbs.kzyplc.com/post/496_1_1.html canada\u0027s indigenous constitution john borrowsWeb23 feb. 2024 · I need help with finding the source of this error. I have taken the project to a VM where I have used the PLCSIM. Deleted OB122 & 121 to see if that got me further … fisher c 20 turntableWebOB122_BLK_TYPE BYTE Description Type of block where the error occurred (B#16#88: OB, B#16#8C: FC, B#16#8E: FB) (no valid number is entered here for an S7-300) … canada\u0027s highest military awardWeb10 mrt. 2014 · I/O access error, reading P area, word access, Access address: 384 Requested OB: I/O access error OB (OB122) Priority class: 1 External error, Incoming … fisher byrialsenWeb30 jul. 2010 · 292 ilgili modulun adresini gösterir ayrıca çapraz adres tablosundan da bakarak anlaşılabilir. Ayrıca arızalı ilgili modullerin BF ve SF ledleri ile de anlaşılır. … fisher c1 pneumatic pressure controller